当前位置:仪器交易网 » 供应 » 仪器配件 » 色谱柱 » 浩瀚色谱(山东)应用技术开发有限公司 » 专用填充柱

联系我们

公司名称:浩瀚色谱(山东)应用技术开发有限公司

联系人:王晓莹

电话:0632-5667636

手机:15562228838(微信同号)13963221227(微信同号)

传真:0632-5667636

邮件:wangxiaoying9@126.com

地址:山东省滕州市(商务和技术部);

会员站:http://www.haohansepuyiqi.com

产品详情

405有机担体填充色谱柱

  • 产品/服务:405有机担体填充色谱柱
  • 品 牌:浩瀚色谱
  • 单 价:面议 
  • 更新日期:2023-06-14
  • 有效期至:长期有效
  • 浏览次数:1097
产品简介

405有机担体填充色谱柱,非甲烷总烃,液化石油气,顶空进样器,粗苯,三苯,二甲苯,芝麻香白酒,3-甲硫基丙醇,液化石油气,顶空进样器...

产品详细介绍
405有机担体填充色谱柱
405有机担体填充色谱柱 详细信息:

05有机担体


名称

组成

颜色

堆密度/g·ml-1

比表面

使用温度/℃

主要分析用途

/m2·g-1

405

二乙烯苯.三氯乙烯共聚物

--

--

<150

较强

--

--


Specification: 2m*3mm
Model: 405 organic carrier
Application: Determination of water, aldehydes, alcohols, ketones

规格:2m*3mm

型号:405有机担体

应用:水,醛,醇,酮的测定


405有机担体填充色谱柱 测试谱图:


Each column is rigorously tested
Full range of columns
Reliable technical support
Years of accumulated chromatographic analysis experience and technical team
Quality assurance:
High-quality stainless steel tubes, glass tubes and chromatographic packings for a variety of highly efficient packed columns
If you need to use stainless steel filter as the plug at both ends of the column, please specify when ordering.
If an on-column injection is used, there will be 6 CM of space at the front of the column inlet.
In order to prevent the elution of the chromatographic packing, both ends of the column are sealed with silanized glass wool.
If a valve injection or non-column injection column is used, the column inlet is filled
Glass column configuration for a wide range of gas chromatographs
2mm inner diameter glass column tube has a bevel at the entrance to facilitate injection
Each column is fully aging and rigorously evaluated
Precautions
Thank you for purchasing the column produced by Haohao.
Every column provided by Haohao is aging. To ensure the analytical separation you get, please aging for 1-2 hours before use. When aging, the carrier gas should be passed for about 10 minutes. After the air in the column is replaced, the temperature is raised to the high temperature of the Zui.
To avoid contamination of the detector, do not connect the column to the detector during aging.
When the oven temperature is higher than room temperature, a small amount of oxygen in the carrier gas will damage the stationary phase in the column. The carrier gas must be further deoxidized by a deoxidizing tube (it is recommended that the oxygen content of the carrier gas used should not exceed 1 ppm)
When installing the column, the product grade should be facing the operator.



如果您觉得“405有机担体填充色谱柱”描述资料不够齐全,请联系我们获取详细资料。(联系时请告诉我从仪器交易网看到的,我们将给您最大优惠!)
本页链接:http://www.yi7.com/com_haohansepu/sell/itemid-8474192.html
已经有1097位访客查看了本页.
产品咨询
* 询价标题:   
快捷提问: (不用打字 “快捷提问”帮您忙!)
* 主要内容:
我希望在 日前回复
公司名:
*联系人:
*联系电话:
电子邮箱:
QQ :
* 验证码:  
没有合适的产品?是否在线询价?
询价标题
联系人
电话
主要内容
验证码