产品详情

GDX-202不锈钢填充柱

  • 产品/服务:GDX-202不锈钢填充柱
  • 品 牌:浩瀚色谱
  • 单 价:面议 
  • 更新日期:2022-09-11
  • 有效期至:长期有效
  • 浏览次数:1784
产品简介

GDX-202不锈钢填充柱,GDX-201,GDX-203,GDX-301,GDX-302,GDX-303,GDX-401,GDX-403,GDX-501,GDX-502...

产品详细介绍
GDX-202不锈钢填充柱
GDX-202不锈钢填充柱 详细信息:

固定相:苯乙烯、二乙烯苯等共聚物

粒度:80-100目/60-80目
材质:不锈钢

规格:2m*3mm

应用:分析高沸点化合物所需时间短、还可分离正丙醇—特丁醇

滕州市浩瀚色谱仪器技术服务有限公司,采用顶空气相色谱法测定了氯乙烯生产过程产生的盐酸溶液中的乙炔和氯乙烯.使用氢氧化钠将试样中的氯化氢中和,从而消除其在气相色谱分析乙炔和氯乙烯中的影响.顶空平衡温度为35 ℃,平衡时间为45 min,色谱柱为填充了GDX-202固定相的2 m×3 mm i.d.不锈钢柱,柱温140 ℃.顶空气体进样量为1 mL.以外标法定量,乙炔含量测定结果的相对标准偏差为0.85%;当其含量为30.0 μg/g~150 μg/g时,回收率为98.9%~103%.氯乙烯含量测定结果的相对标准偏差为1.4%;当其含量为20.0 μg/g~100 μg/g时,回收率为98.8%~102%.

GDX-202不锈钢填充柱 图片:



GDX-202 stainless steel packed column
GDX-202 stainless steel packed column Details:

Stationary phase: copolymers such as styrene and divinylbenzene
Particle size: 80-100 mesh / 60-80 mesh
Material: Stainless steel
Specification: 2m*3mm
Application: Analysis of high boiling point compounds takes a short time and can also separate n-propanol-butanol

Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. used apex air phase chromatography to determine acetylene and vinyl chloride in hydrochloric acid solution produced by vinyl chloride production. Neutralization of hydrogen chloride in the sample was carried out using sodium hydroxide, thereby eliminating The effect of acetylene and vinyl chloride was analyzed by gas chromatography. The headspace equilibrium temperature was 35 °C, the equilibrium time was 45 min, and the column was a 2 m × 3 mm id stainless steel column filled with GDX-202 stationary phase. The column temperature was 140 °C. The head air injection volume is 1 mL. The external standard method quantifies the relative standard deviation of the acetylene content measurement to 0.85%; when the content is 30.0 μg/g to 150 μg/g, the recovery rate is 98.9% to 103%. The relative standard deviation of the determination of vinyl chloride content is 1.4%; when the content is 20.0 μg / g ~ 100 μg / g, the recovery is 98.8% ~ 102%.

GDX-202 stainless steel packed column


如果您觉得“GDX-202不锈钢填充柱”描述资料不够齐全,请联系我们获取详细资料。(联系时请告诉我从仪器交易网看到的,我们将给您最大优惠!)
本页链接:http://www.yi7.com/com_haohansepu/sell/itemid-8676515.html
已经有1784位访客查看了本页.
产品咨询
* 询价标题:   
快捷提问: (不用打字 “快捷提问”帮您忙!)
* 主要内容:
我希望在 日前回复
公司名:
*联系人:
*联系电话:
电子邮箱:
QQ :
* 验证码:  
没有合适的产品?是否在线询价?
询价标题
联系人
电话
主要内容
验证码