Tenax-TA 吸附管测定室内TVOC污染物

  • 产品/服务:Tenax-TA 吸附管测定室内TVOC污染物
  • 型 号:Tenax-TA
  • 品 牌:浩瀚色谱
  • 单 价:面议 
  • 更新日期:2023-07-05
  • 有效期至:长期有效
  • 浏览次数:1196
产品简介

Tenax-TA吸附管测定室内TVOC污染物,热解吸仪,裂解进样器,多氯联苯,植物油,6号溶剂残留,环氧乙烷,三甲胺,二甲醚,甲醇,甲酸,乙酸乙酯,甲醛,非甲烷总烃...

产品详细介绍
Tenax-TA吸附管测定室内TVOC污染物
Tenax-TA吸附管测定室内TVOC污染物 详细信息:

固定相:Tenax-TA

粒度:60-80目

规格:1/4*3.5英寸,6*150mm,6*90,填料200mg,其他规格可定制

材质:玻璃,不锈钢

应用:GB_50325-2010_民用建筑工程室内环境污染控制规范

滕州市浩瀚色谱仪器技术服务有限公司,研究了影响气相色谱法测定室内空气中TVOC(总挥发性有机化合物)浓度的主要因素。采样过程中如流量达不到0 . 5L min ,可通过延长采样时间使终采样体积达到10L ;采样前延长通风时间使室内外空气充分对流,有利于室内残留污染物质的扩散,能反映重新封闭后有机挥发物1h时段内释放的实际浓度。TVOC各组分的热解吸率与该组分的分子量和性有关;热解吸率随解吸时间的延长而降低,操作中以1~3min比较合适。将初始柱温从5 0℃提高到70℃,不设停留时间,终止温度从2 5 0℃降为2 30℃,可以将样品分析时间由5 5min缩短到32min而对分析结果几乎没有影响。


Tenax-TA吸附管测定室内TVOC污染物 图片:




Determination of indoor TVOC pollutants by Tenax-TA adsorption tube
Tenax-TA adsorption tube for measuring indoor TVOC pollutants

Stationary Phase: Tenax-TA
Particle size: 60-80 mesh
Specifications: 1/4*3.5 inches, 6*150mm, 6*90, packing 200mg, other specifications can be customized
Material: glass, stainless steel
Application: GB_50325-2010_Code for indoor environmental pollution control of civil construction projects

Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. studied the main factors affecting the determination of TVOC (total volatile organic compounds) in indoor air by gas chromatography. If the flow rate does not reach 0. 5L min during the sampling process, the final sampling volume can reach 10L by extending the sampling time. The ventilation time is extended before sampling to make the indoor and outdoor air convect fully, which is beneficial to the diffusion of residual pollutants in the room and can reflect the re-enclosure. The actual concentration of post-organic volatiles released during the 1 h period. The thermal desorption rate of each component of TVOC is related to the molecular weight and polarity of the component; the thermal desorption rate decreases with the extension of the desorption time, and it is suitable for 1 to 3 minutes in the operation. Increasing the initial column temperature from 50 °C to 70 °C without stopping time, the termination temperature was reduced from 250 °C to 2 30 °C, and the sample analysis time was shortened from 55 min to 32 min with little effect on the analytical results.


Determination of Indoor TVOC Contaminants by Tenax-TA Adsorption Tube


如果您觉得“Tenax-TA 吸附管测定室内TVOC污染物”描述资料不够齐全,请联系我们获取详细资料。(联系时请告诉我从仪器交易网看到的,我们将给您最大优惠!)
本页链接:http://www.yi7.com/com_haohansepu/sell/itemid-8689861.html
已经有1196位访客查看了本页.
产品咨询
* 询价标题:   
快捷提问: (不用打字 “快捷提问”帮您忙!)
* 主要内容:
我希望在 日前回复
公司名:
*联系人:
*联系电话:
电子邮箱:
QQ :
* 验证码:  
没有合适的产品?是否在线询价?
询价标题
联系人
电话
主要内容
验证码