提交询价信息 |
发布紧急求购 |
型号
|
正常流量范围m3/h
|
下限扩大范围m3/h
|
工作压力MPa
|
G型工作压力MPa
|
Z型工作压力MPa
|
D型工作压力MPa
|
公称通径MM
|
GLW4
|
0.04-0.25
|
6.4
|
2.5
|
4
|
|||
GLW6
|
0.1-0.6
|
6.4
|
2.5
|
6
|
|||
GLW10
|
0.2-1.2
|
25
|
25
|
2.5
|
10
|
||
GLW15
|
0.7-6
|
0.6-6
|
32
|
32
|
6.4
|
2.5
|
15
|
GLW25
|
1.2-10
|
1-10
|
50 25
|
50
|
6.4
|
2.5
|
25
|
GLW40
|
2.5-20
|
2-20
|
50 25
|
50
|
6.4
|
2.5
|
40
|
GLW50
|
5-40
|
4-40
|
50 2.5
|
50
|
6.4
|
2.5
|
50
|
GLW80
|
12-100
|
10-100
|
32 2.5
|
32
|
6.4
|
2.5
|
80
|
GLW100
|
25-200
|
20-200
|
32 2.5
|
6.4
|
2.5
|
100
|
|
GLW150
|
50-400
|
40-400
|
2.5 1.6
|
6.4
|
2.5
|
150
|
|
GLW200
|
100-800
|
80-800
|
2.5 1.6
|
6.4
|
2.5
|
200
|
|
GLW250
|
150-1200
|
120-1200
|
2.5 1.6
|
6.4
|
2.5
|
250
|
|
GLW300
|
300-2500
|
250-2500
|
1.6
|
6.4
|
2.5
|
300
|
公称通径(mm)
|
L(mm)
|
H(mm)
|
G
|
L’
|
D(mm)
|
d(mm)
|
孔数
|
|
GLW-4
|
4
|
275
|
145
|
G1/2
|
215
|
|||
GLW-6
|
6
|
275
|
145
|
G1/2
|
215
|
|||
GLW-10
|
10
|
455
|
165
|
G1/2
|
350
|
|||
GLW-15
|
15
|
75
|
173
|
G1
|
||||
GLW-25
|
25
|
100
|
180
|
G5/4
|
||||
GLW-40
|
40
|
140
|
178
|
G2
|
||||
GLW-50
|
50
|
150
|
252
|
Ф125
|
Ф18
|
4
|
||
GLW-80
|
80
|
200
|
287
|
Ф160
|
Ф18
|
8
|
||
GLW-100
|
100
|
220
|
322
|
Ф180
|
Ф18
|
8
|
||
GLW-150
|
150
|
300
|
367
|
Ф250
|
Ф25
|
8
|
||
GLW-200
|
200
|
360
|
410
|
Ф310
|
Ф25
|
12
|
||
GLW-250
|
250
|
420
|
460
|
Ф370
|
Ф30
|
12
|
||
GLW-300
|
300
|
432
|
550
|
Ф430
|
Ф30
|
16
|
序号
|
故障现象
|
原因
|
消除方法
|
1
|
显示仪对流量信号和检验信号均无显示
|
1. 电源未接通,给定电压不对。
2. 显示仪有故障。
|
1. 接通电源,按要求给定电压。
2. 检修显示仪表。
|
2
|
显示仪表对“校验”信号有显示但对流量信号无显示。
|
1. 传感器与显示仪间接线有误,或者有开路,短路,接线不良等故障。
2. 放大器有故障或损坏。
3. 转换器(线圈)开路或短路。
4. 叶轮被卡住。管道无流体流动或堵塞。
|
1. 检查接线的正确性和接线质量。
2. 维修或更换放大器。
3. 维修或更换线圈。
4. 清洗传感器及管道。开通阀门或泵,清洗管道。
|
3
|
显示仪表工作不稳;计量不正确。
|
1. 实际流量超出仪表的计量范围或不稳定。
2. 仪表系数K设置有误。
3. 传感器内挂上纤维等杂质。
4. 液体内有气泡存在。
5. 传感器旁有较强的电磁场干扰。
6. 传感器轴承及轴严重磨损。
7. 传感器电缆屏蔽层或其它接地导线与线路地线断开或接触不良。
8. 显示仪表故障。
|
1. 使被测流量与传感器的测量范围相适应,并稳定流量。
2. 使系数K设置正确。
3. 清洗传感器。
4. 采取消气措施,消除气泡。
5. 尽量远离干扰源或采取屏蔽措施。
6. 更换“向导件”或“也轮轴”。
7. 将线接好。
8. 检修显示仪表。
|